首页 > 新闻中心 > 服务支持<
以下是中试控股串联谐振方案大全,希望可以帮助您更好的解决串联谐振耐压试验的试验
|
产品型号及方案名称 |
试品对象适用范围 |
主要配置参数 |
|||||||
|
变频源(台) |
励磁变(台) |
电抗器(节) |
分压器(台) |
电容器(台 ) |
|||||
|
XZB-36kVA/18kV |
10kV/300mm2电缆1km |
4kVA/10A |
4kVA |
18kV/1A |
30kV |
|
|||
|
调频式串联谐振试验装置 |
(1台) |
(1台) |
(2台) |
(1台) |
|||||
|
试验频率:30~300Hz |
|
|
|
2000pF |
|||||
|
|
|
|
|
|
|
|
|||
|
XZB-44kVA/22kV |
10kV/240mm2电缆500m |
3kW/8A |
3kVA |
22kV/1A |
30kV |
|
|||
|
调频式串联谐振试验装置 |
(1台) |
(1台) |
(2台) |
2000pF |
|||||
|
试验频率:30~300Hz |
10kV/180mm2电缆1000m |
|
|
|
(1台) |
||||
|
|
|
|
|
|
|
|
|||
|
XZB-50kVA/50kV |
20kV,400mm2电缆200m |
3kW/7.8A |
3kVA |
25kV/1A |
50kV |
|
|||
|
调频式串联谐振耐压装置 |
(1台) |
(1台) |
(2台) |
2000pF |
|||||
|
试验频率:30~300Hz |
|
|
|
(1台) |
|||||
|
|
|
|
|
|
|
|
|||
|
XZB-54kVA/18kV |
6kV/180mm2电缆 |
4.5kW/12A |
4.5kVA |
18kV/1A |
30kV |
|
|||
|
调频式串联谐振试验装置 |
(1台) |
(1台) |
(3台) |
3000pF |
|||||
|
试验频率:30~300Hz |
|
|
|
(1台) |
|||||
|
|
|
|
|
|
|
|
|||
|
XZB-54kVA/54kV |
35kV/300mm2长度500m电缆 |
4.5kW/10A |
4.5kVA |
18kV/1A |
60kV |
|
|||
|
变频串联谐振试验装置 |
(1台) |
(1台) |
(3台) |
2000pF |
|||||
|
试验频率:30~300Hz |
10kV/300mm2长度500m电缆 |
|
|
|
(1台) |
||||
|
|
|
|
|
|
|
|
|||
|
XZB-72kVA/18kV |
满足≤2km长 6kV(240mm2)电缆的变频交流耐压试验 |
4kW/10.5A |
4kVA |
36kV/2A |
25kV |
|
|||
|
调频式串联谐振试验装置 |
(1台) |
(1台) |
(2台) |
18pF |
|||||
|
试验频率:30~300Hz |
|
|
|
(1台) |
|||||
|
|
|
|
|
|
|
|
|||
|
XZB-73kVA/22kV |
10kV/300mm2电缆1.5km |
6kW/15A |
6kVA |
36.5kV |
30kV |
|
|||
|
调频式串联谐振试验装置 |
(1台) |
(1台) |
1.66A |
2000pF |
|||||
|
试验频率:30~300Hz |
|
|
(2台) |
(1台) |
|||||
|
|
|
|
|
|
|
|
|||
|
XZB-80kVA/40kV |
10kV,300mm2电缆2km |
4kW/10A |
4kVA |
40kV/2A |
40kV |
|
|||
|
调频式串联谐振耐压装置 |
(1台) |
(1台) |
(2台) |
2000pF |
|||||
|
试验频率:30-300Hz |
|
|
|
(1台) |
|||||
|
|
|
|
|
|
|
|
|||
|
XZB-81kVA/54kV |
6kV/300mm2,长度500m电缆 |
4.5kW/12A |
4.5kVA |
27kV/1.8A |
60kV |
|
|||
|
高压电缆交流耐压试验装置 |
10kV/300mm2,长度500m电缆 |
(1台) |
(1台) |
(3台) |
1000pF |
||||
|
试验频率:30-300Hz |
35kV/300mm2,长度500m电缆 |
|
|
|
(1台) |
||||
|
|
|
|
|
|
|
|
|||
|
XZB-88kVA/22kV |
10kV/300mm2电缆,长度2000m |
6kW/15A |
6kVA |
22kV/1A |
30kV |
|
|
||
|
10kV交联电缆交流耐压装置 |
(1台) |
(1台) |
(4台) |
1000pF |
|
||||
|
试验频率:30-300Hz |
|
|
|
(1台) |
|
||||
|
|
|
|
|
|
|
|
|
||
|
XZB-88kVA/22kV |
10kV/400mm2电缆2km |
6kW/15A |
6kVA |
44kV/2A |
30kV |
|
|
||
|
调频式串联谐振试验装置 |
(1台) |
(1台) |
(2台) |
2000pF |
|
||||
|
试验频率:30-300Hz |
|
|
|
(1台) |
|
||||
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
||
|
XZB-88kVA/22kV |
10kV/240mm2电缆2km |
6kW/15A |
6kVA |
44kV/2A |
30kV |
|
|
||
|
调频式串联谐振试验装置 |
(1台) |
(1台) |
(2台) |
2000pF |
|
||||
|
试验频率:30-300Hz |
|
|
|
(1台) |
|
||||
|
|
|
|
|
|
|
|
|
||
|
XZB-90kVA/18kV |
6kV/300mm2电缆,长度3000m |
5kW/12.5A |
5kVA |
30kV |
30kV |
|
|
||
|
6kV交联电缆交流耐压装置 |
(1台) |
(1台) |
1.67A |
1000pF |
|
||||
|
试验频率:30-300Hz |
|
|
|
(3台) |
1(台) |
|
|||
|
XZB-108kVA/54kV |
35KV/300mm2,长度1km以内电缆 |
6kW/15A |
6kVA |
27kV/1A |
60kV |
|
|
||
|
调频式串联谐振耐压装置 |
(1台) |
(1台) |
(4台) |
1000pF |
|
|
|||
|
试验频率:30-300Hz |
|
|
|
|
(1台) |
|
|||
|
|
|
|
|
|
|
|
|
||
|
XZB-132kVA/22kV/66kV |
35kV/300mm2电缆 |
6kW/15A |
6kVA |
44kV/2A |
60kV |
隔离 |
|
||
|
变频串联谐振试验装置 |
(1台) |
(1台) |
(3台) |
1500pF |
变压器 |
|
|||
|
试验频率:30-300Hz |
10kV/300mm2电缆b |
|
|
|
(1台) |
6kV (1台) |
|
||
|
|
|
|
|
|
|
|
|
||
|
XZB-132kVA/22kV |
10kV/400mm2电缆 |
6kW/15A |
6kVA |
44kV/2A |
30kV |
|
|
||
|
变频串联谐振试验装置 |
(1台) |
(1台) |
(3台) |
2000pF |
|
||||
|
试验频率:30-300Hz |
|
|
|
|
(1台) |
|
|||
|
|
|
|
|
|
|
|
|
||
|
XZB-132kVA/22kV |
6kV/300mm2电缆 |
7.5kW/20A |
7.5kVA |
44kV/2A |
25kV |
|
|
||
|
变频串联谐振试验装置 |
(1台) |
(1台) |
(3台) |
2000pF |
|
||||
|
试验频率:30-300Hz |
|
|
|
|
(1台) |
|
|||
|
|
|
|
|
|
|
|
|
||
|
XZB-132kVA/25kV |
10kV/2400mm2电缆 |
6kW/15A |
6kVA |
44kV/1.76A |
30kV |
|
|
||
|
变频串联谐振试验装置 |
10kV/1850mm2电缆 |
(1台) |
(1台) |
(3台) |
2000pF |
|
|||
|
试验频率:30-300Hz |
10kV/1500mm2电缆 |
|
|
|
(1台) |
|
|||
|
|
10kV/1200mm2电缆 |
|
|
|
|
|
|||
|
|
10kV/950mm2电缆 |
|
|
|
|
|
|||
|
|
10kV/700mm2电缆 |
|
|
|
|
|
|||
|
|
10kV/500mm2电缆 |
|
|
|
|
|
|||
|
|
10kV/350mm2电缆 |
|
|
|
|
|
|||
|
|
10kV/250mm2电缆 |
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
||
|
XZB-132kVA/5kV |
可满足10kV高压电缆 |
10kW/50A |
6kVA |
22kV/2A |
60kV |
|
|
||
|
变频串联谐振试验装置 |
(1台) |
(1台) |
(3台) |
1000pF |
|
||||
|
试验频率:30-300Hz |
可满足35kV高压电缆 |
|
|
|
(1台) |
|
|||
|
|
|
|
|
|
|
|
|
||
|
XZB-135kVA/54kV |
35kV,3000mm2交联电缆1000m |
7.5kW/20A |
7.5kVA |
33.75kV |
60kV |
|
|
||
|
调频式串联谐振耐压装置 |
(1台) |
(1台) |
1.25A |
2000pF |
|
||||
|
试验频率:30-300Hz |
10kV,300mm2交联电缆3000m |
|
|
(4台) |
(1台) |
|
|||
|
|
|
|
|
|
|
|
|
||
|
XZB-135kVA/54kV |
35kV,4000mm2交联电缆1000m |
7.5kW/20A |
7.5kVA |
33.75kV |
60kV |
|
|
||
|
调频式串联谐振耐压装置 |
(1台) |
(1台) |
1.25A |
2000pF |
|
||||
|
试验频率:30-300Hz |
|
|
(4台) |
(1台) |
|
||||
|
|
10kV,240mm2交联电缆3000m |
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
||
|
BPXZ-162kVA/54kV/27kV |
35kV电缆,400mm2,长度1000m |
9kW/24A |
9kVA |
40.5kV |
60kV |
|
|
||
|
调频式串联谐振耐压装置 |
(1台) |
(1台) |
1.5A |
1000pF |
|
||||
|
试验频率:30-300Hz |
10kV电缆,300mm2,长度3000m |
|
|
(4台) |
(1台) |
|
|||
|
|
|
|
|
|
|
|
|
||
|
XZB-176kVA/22kV |
10kV/630mm2电缆3km |
80kW/21A |
80kVA |
44kV/2A |
30kV |
|
|
||
|
调频式串联谐振试验装置 |
(1台) |
(1台) |
(4台) |
2000pF |
|
||||
|
试验频率:30-300Hz |
|
|
|
|
(1台) |
|
|||
|
|
|
|
|
|
|
|
|
||
|
XZB-198kVA/22kV |
10kV/630mm2电缆3.5km |
9kW/23.6A |
9kVA |
49.5kV |
30kV |
|
|
||
|
调频式串联谐振试验装置 |
(1台) |
(1台) |
2.25A |
2000pF |
|
||||
|
试验频率:30-300Hz |
|
|
|
(4台) |
(1台) |
|
|||
|
|
|
|
|
|
|
|
|
||
|
XZB-216kVA/54kV/27kV |
35kV/300mm2 电缆2000m |
10kW/26.3A |
10kVA |
154kVA/2A |
60kV |
|
|
||
|
变频串联谐振试验装置 |
10kV/300mm2 电缆4000m |
(1台) |
(1台) |
(4台) |
(1台) |
|
|||
|
试验频率:30~300Hz |
10kV/150mm2 电缆5000m |
|
|
|
1000pF |
|
|||
|
|
10kV/120mm2 电缆5500m |
|
|
|
|
|
|||
|
|
10kV/90mm2 电缆6000m |
|
|
|
|
|
|||
|
|
10kV/50mm2 电缆7500m |
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
||
|
XZB-216kVA/54kV |
35kV/240mm2 电缆2000m |
10kW/25A |
10kVA |
54kVA/2A |
60kV |
|
|
||
|
变频串联谐振试验装置 |
(1台) |
(1台) |
(4台) |
(1台) |
|
||||
|
试验频率:30~300Hz |
10kV/300mm2 电缆4000m |
|
|
|
1500pF |
|
|||
|
|
|
|
|
|
|
|
|
||
|
XZB-216kVA/54kV |
35kV/240mm2,长度2km以内 |
10kW/26A |
10kVA |
54kVA/2A |
60kV |
|
|
||
|
调频式串联谐振耐压装置 |
(1台) |
(1台) |
(4台) |
(1台) |
|
||||
|
试验频率:30~300Hz |
|
|
|
|
1000pF |
|
|||
|
|
|
|
|
|
|
|
|
||
|
XZB-216kVA/54kV |
35kV/300mm2,长度2km以内 |
10kW/26A |
10kVA |
54kVA/2A |
60kV |
|
|
||
|
调频式串联谐振耐压装置 |
(1台) |
(1台) |
(4台) |
(1台) |
|
||||
|
试验频率:30~300Hz |
|
|
|
|
1000pF |
|
|||
|
|
|
|
|
|
|
|
|
||
|
TFL-HT-250kVA/25kV |
电缆截面积25~50mm2 |
4kVA/10A |
40kVA |
250KVA/10A |
30kV |
30kV |
|
||
|
调感式串联谐振试验装置 |
(1台) |
(1台) |
(1台) |
(1台) |
(1台) |
|
|||
|
试验频率:工频50Hz |
|
|
|
|
|
0.22μF |
|
||
|
|
|
|
|
|
|
|
|
||
|
XZB-264kVA/22kV/66kV |
10kV/300mm2 电缆5km |
15kW/40A |
15kVA |
88kVA/4A |
70kV |
|
|
||
|
调频式串联谐振试验装置 |
(1台) |
(1台) |
(3台) |
(1台) |
|
||||
|
试验频率:30~300Hz |
5kV/300mm2 电缆1.5km |
|
|
|
2000pF |
|
|||
|
|
|
|
|
|
|
|
|
||
|
XZB-264kVA/22kV |
10kV/300mm2 电缆6km |
18kW/47.5A |
18kV |
44kVA/2A |
30kV |
|
|
||
|
调频式串联谐振试验装置 |
(1台) |
(1台) |
(6台) |
(1台) |
|
||||
|
试验频率:30~300Hz |
|
|
|
|
2000pF |
|
|||
|
|
|
|
|
|
|
|
|
||
|
XZB-264kVA/54kV |
35kV/300mm2 电缆1500m |
10kW/25A |
10kVA |
44kVA/2A |
60kV |
|
|
||
|
变频串联谐振试验装置 |
(1台) |
(1台) |
(6台) |
(1台) |
|
||||
|
试验频率:30~300Hz |
|
|
|
1500pF |
|
||||
|
|
|
|
|
|
|
||||
|
|
10kV/300mm2 电缆4000m |
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
||
|
XZB-264kVA/66kV |
35kV/300mm2 电缆1500m |
10kW/25A |
10kVA |
44kVA/2A |
70kV |
隔离变 |
|
||
|
变频串联谐振试验装置 |
(1台) |
(1台) |
(2台) |
(1台) |
10kVA |
|
|||
|
试验频率:30~300Hz |
10kV/300mm2 电缆4000m |
|
|
|
1000pF |
|
|
||
|
|
|
|
|
|
|
|
|
||
|
XZB-270kVA/54kV |
35kV/150mm2 电缆3km |
15kW/37.5A |
15kVA |
67.5kVA |
60kV |
|
|
||
|
变频串联谐振试验装置 |
(1台) |
(1台) |
2.5A |
(1台) |
|
||||
|
试验频率:30~300Hz |
|
|
|
(4台) |
1000pF |
|
|||
|
|
|
|
|
|
|
|
|
||
|
XZB-300kVA/50kV |
20kV/300mm2 电缆2000m |
15kW/40A |
15kVA |
75kVA/3A |
50kV |
|
|
||
|
变频串联谐振试验装置 |
(1台) |
(1台) |
(4台) |
(1台) |
|
||||
|
试验频率:30~300Hz |
|
|
|
|
1000pF |
|
|||
|
|
|
|
|
|
|
|
|
||
|
XZB-300kVA/150kV |
100000kVA/110kV 电力变压器 |
20kW/53A |
20kVA |
100kVA/2A |
150kV |
|
|
||
|
变频串联谐振试验装置 |
(1台) |
(1台) |
(3台) |
(1台) |
|
||||
|
试验频率:30~300Hz |
660MW/22kV 火力发电机 |
|
|
|
1000pF |
|
|||
|
|
|
|
|
|
|
|
|
||
|
XZB-300kVA/600kV |
10kV/300mm2 电缆1km |
15kW/40A |
15kVA |
100kVA/0.5A |
600kV |
|
|
||
|
调频式串联谐振试验装置 |
(1台) |
(1台) |
(3台) |
(1台) |
|
||||
|
试验频率:30~300Hz |
|
|
|
|
400pF |
|
|||
|
|
|
|
|
|
|
|
|
||
|
XZB-320kVA/128kV |
110KV/185mm2 电缆0.5km |
15kW/40A |
15kVA |
80kVA/2.5A |
150kV |
|
|
||
|
调频式串联谐振耐压装置 |
(1台) |
(1台) |
(4台) |
(1台) |
|
||||
|
试验频率:30~300Hz |
|
|
|
|
1000pF |
|
|||
|
|
|
|
|
|
|
|
|
||
|
XZB-324kVA/54kV |
35kV/300mm2 电缆3000m |
18kW/47A |
18kVA |
54kVAV/2A |
60kV |
|
|
||
|
变频串联谐振试验装置 |
(1台) |
(1台) |
(6台) |
(1台) |
|
||||
|
试验频率:30~300Hz |
10kV/300mm2 电缆5000m |
|
|
|
2000pF |
|
|||
|
|
|
|
|
|
|
|
|
||
|
TFL-HT-350kVA/30kV |
电缆300mm2长度2000m |
调压器 |
36kVA |
350KVA |
30kV |
|
|
||
|
调感式串联谐振试验装置 |
40kVA |
(1台) |
11.6A |
(1台) |
|
||||
|
试验频率:工频50Hz |
|
(1台) |
|
(1台) |
|
|
|||
|
|
|
|
|
|
|
|
|
||
|
XZB-360kVA/45kV |
20kV/300mm2 电缆3000m |
25kW/62.5A |
25kVA |
90kVA/2A |
50kV |
|
|
||
|
变频串联谐振试验装置 |
(1台) |
(1台) |
(4台) |
(1台) |
|
||||
|
试验频率:30~300Hz |
|
|
|
|
1000pF |
|
|||
|
|
|
|
|
|
|
|
|
||
|
XZB-375kVA/250kV |
132kV 电缆100mm2 |
12kW/31.5A |
12kVA |
75kVA/1.5A |
250kV |
|
|
||
|
调频式串联谐振耐压装置 |
(1台) |
(1台) |
(5台) |
(1台) |
|
||||
|
试验频率:30~300Hz |
|
|
|
|
1000pF |
|
|||
|
|
|
|
|
|
|
|
|
||
|
XZB-378kVA/54kV |
35kV/300mm2 电缆3000m |
20kW/53A |
10kVA |
94.5kVA |
60KV |
|
|
||
|
调频式串联谐振耐压装置 |
(1台) |
(1台) |
3.5A |
(1台) |
|
||||
|
试验频率:30~300Hz |
|
|
|
(4台) |
1500pF |
|
|||
|
|
|
|
|
|
|
|
|
||
|
XZB-405kVA/54kV |
10kV/300mm2 电缆8km |
25kW/62.5A |
25kVA |
67.5kVA |
60kV |
|
|
||
|
调频式串联谐振耐压装置 |
(1台) |
(1台) |
2.5A |
(1台) |
|
||||
|
试验频率:30~300Hz |
35kV/300mm2 电缆3km |
|
|
(6台) |
1500pF |
|
|||
|
|
|
|
|
|
|
|
|
||
|
XZB-455kVA/130kV |
35kV/300mm2电缆,长度2000m |
15kW/380V |
15kVA |
150kVA |
130kV |
|
|
||
|
变频串联谐振试验装置 |
(1台) |
(1台) |
(3台) |
(1台) |
|
||||
|
试验频率:30~300Hz |
|
|
|
750pF |
|
||||
|
|
110kV/300mm2电缆,长度800m |
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
||
|
XZB-648kVA/54kV |
35kV/300mm2电缆长度5km |
36kW/380V |
18kVA |
162kVA |
60kV |
|
|
||
|
调频式串联谐振耐压装置 |
(1台) |
(1台) |
(4台) |
(1台) |
|
||||
|
试验频率:30~300Hz |
|
|
|
|
1500pF |
|
|||
|
|
|
|
|
|
|
|
|
||
|
BPXZ648kVA/135kV/45kV |
35kV/300mm2,长度3000m电缆 |
24kW/380V |
24kVA |
72kVA |
130kV |
|
|
||
|
调频式串联谐振耐压装置 |
(1台) |
(1台) |
(9台) |
(1台) |
|
||||
|
试验频率:30~300Hz |
110kV/400mm2长度1000m电缆 |
|
|
|
1000pF |
|
|||
|
|
|
|
|
|
|
|
|
||
|
XZB-680kVA/85kV |
27.5kV/400mm2电缆2km |
24kW/380V |
24kVA |
85kVA |
90kV |
|
|
||
|
变频串联谐振试验装置 |
(1台) |
(1台) |
(8台) |
(1台) |
|
||||
|
试验频率:30~300Hz |
|
|
|
|
1000pF |
|
|||
|
|
|
|
|
|
|
|
|
||
|
XZB-810kVA/135kV/45kV |
35kV/300mm2,长度3000m电缆 |
40kW/380V |
20kVA |
67.5kVA |
130kV |
|
|
||
|
调频式串联谐振耐压装置 |
(1台) |
(2台) |
(12台) |
(1台) |
|
||||
|
试验频率:30~300Hz |
110kV/400mm2长度1000m电缆 |
|
|
|
1000pF |
|
|||
|
|
|
|
|
|
|
|
|
||
|
XZB-990kVA/132kV |
110KV/400mm2电缆1.5km以内 |
45kW/380V |
45kVA |
165kVA |
150kV |
|
|
||
|
调频式串联谐振耐压装置 |
(1台) |
(1台) |
(6台) |
(1台) |
|
||||
|
试验频率:30~300Hz |
|
|
|
|
1000pF |
|
|||
|
|
|
|
|
|
|
|
|
||
|
XZB-1080kVA/54kV |
35kV/300mm2电缆8km以下 |
50kW/380V |
50kVA |
540kVA |
60kV |
|
|
||
|
变频串联谐振试验装置 |
(1台) |
(1台) |
(2台) |
(1台) |
|
||||
|
试验频率:30~300Hz |
|
|
|
|
1500pF |
|
|||
|
|
|
|
|
|
|
|
|
||
|
XZB-1320kVA/220kV |
220kV,2400mm2电缆0.5km |
48kW/380V |
48kVA |
660kVA |
220kV |
|
|
||
|
调频式串联谐振耐压装置 |
(1台) |
(1台) |
(2台) |
(1台) |
|
||||
|
试验频率:30-300Hz |
|
|
|
|
700pF |
|
|||
|
|
|
|
|
|
|
|
|
||
|
XZB-1540kVA/220kV |
220kV/500mm2电缆1km |
56kW/380V |
56kVA |
770kVA |
220kV |
|
|
||
|
调频式串联谐振耐压装置 |
(1台) |
(1台) |
(2台) |
(1台) |
|
||||
|
试验频率:30~300Hz |
|
|
|
700pF |
|
||||
|
|
|
|
|
|
分两节 |
|
|||
|
|
|
|
|
|
|
|
|
||
|
XZB-1560kVA/130kV |
110kV电缆1200平方截面1.5km |
60kW/380V |
60kVA |
780kVA |
150kV |
|
|
||
|
变频串联谐振试验装置 |
(1台) |
(1台) |
(2台) |
(1台) |
|
||||
|
试验频率:30-300Hz |
35kV电缆300平方截面5km |
|
|
|
1000pF |
|
|||
|
|
|
|
|
|
|
|
|
||
|
XZB-1560kVA/130kV |
110kV/1200mm2电缆1000m |
48kW/380V |
60kVA |
780kVA |
300kV |
|
|
||
|
变频串联谐振试验装置 |
220kV/2400mm2电缆500m |
(1台) |
(1台) |
(2台) |
(1台) |
|
|||
|
试验频率:30-300Hz |
35kV/240mm2电缆3000m |
|
|
|
800pF |
|
|||
|
|
|
|
|
|
|
|
|
||
|
XZB-1980kVA/220kV |
220kV,1000mm2电缆1km |
72kW/380V |
72kVA |
990kVA |
220kV |
|
|
||
|
调频式串联谐振耐压装置 |
(1台) |
(1台) |
(2台) |
(1台) |
|
||||
|
试验频率:30-300Hz |
|
|
|
|
700pF |
|
|||
|
|
|
|
|
|
|
|
|
||
|
XZB-3200kVA/128kV |
64kV/110kV/400mm2,5000m |
125kW/380V |
125kVA |
800kVA |
130kV |
|
|
||
|
调频式串联谐振耐压装置 |
(1台) |
(1台) |
(4台) |
(1台) |
|
||||
|
试验频率:30-300Hz |
|
|
|
1000pF |
|
||||
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
||
|
XZB-4420kVA/130kV |
110KV/800mm2,长度5km以内 |
204kW/380V |
204kVA |
2210kVA |
130kV |
|
|
||
|
调频式串联谐振耐压装置 |
(1台) |
(1台) |
(2台) |
(1台) |
|
||||
|
试验频率:30-300Hz |
|
|
|
|
1000pF |
|
|||
|
|
|
|
|
|
|
|
|
||
|
XZB-21600kVA/216kV |
110kV/1200mm2电缆10km |
1200kW |
1200kVA |
5400kVA |
220kV |
|
|
||
|
调频式串联谐振耐压装置 |
380V |
(1台) |
(4台) |
(1台) |
|
||||
|
试验频率:30-300Hz |
(1台) |
|
|
700pF |
|
||||
上一篇:串联谐振的应用
下一篇:变频串联谐振耐压装置的介绍